Choose by your host and enclosure
The AUO N-series models below span 10.1 to 21.5 inches, but they do not share one interface or temperature rating. Shortlist by the host signal, native resolution and mechanical fit first; then compare brightness, thermal limits and the required backlight circuit.
Compact equipment
N101SAN01.0 provides a 1024 × 600 roadmap reference. For a 10.4-inch 800 × 600 design, compare N104STN01.0 and N104STN01.1 with their separate document bases.
15-inch 4:3 systems
N150XAN01.0 is a 1024 × 768 LVDS option to evaluate. The reviewed preliminary document identifies AHVA and an operating range of −20 to +70 °C.
15.6-inch FHD systems
The N156HAN01.0, .1 and .3 entries use eDP. Their brightness, mechanical details and document revisions differ; a suffix change needs its own review.
21.5-inch FHD systems
N215HAN01.0 is listed with LVDS in the Q4 roadmap. Do not select an eDP controller simply because other N-series FHD models use eDP.
Eight models, with the source kept visible
Use this comparison to form a shortlist. “Preliminary” values refer to the specific revision reviewed, while “Q4 roadmap” values are planning summaries rather than an approved integration specification.
| Model | Size / pixels | Interface | Brightness cd/m² | Temperature reference | Data basis |
|---|---|---|---|---|---|
| N101SAN01.0 | 10.1" 1024 × 600 | Digital | 350 | −10 to +60 °C | Q4 roadmap |
| N104STN01.0 | 10.4" 800 × 600 | Parallel RGB 24 data bits | 450 typ. | −10 to +60 °C Absolute-rating reference* | Preliminary 2024-03-19 |
| N104STN01.1 | 10.4" 800 × 600 | Digital | 350 | −20 to +70 °C | Q4 roadmap |
| N150XAN01.0 | 15" 1024 × 768 | LVDS | 350 typ. | −20 to +70 °C | Preliminary 2024-05-08 |
| N156HAN01.0 | 15.6" 1920 × 1080 | 2-lane eDP 1.2 | 250 typ. | 0 to +50 °C | Preliminary 2024-01-05 |
| N156HAN01.1 | 15.6" 1920 × 1080 | eDP | 320 | 0 to +50 °C | Q4 roadmap |
| N156HAN01.3 | 15.6" 1920 × 1080 | 2-lane eDP 1.2 | 300 typ. | 0 to +50 °C | Preliminary 2026-01-27 |
| N215HAN01.0 | 21.5" 1920 × 1080 | LVDS | 250 | 0 to +60 °C | Q4 roadmap |
Swipe inside the table on smaller screens. *N104STN01.0: the −10 to +60 °C value comes from the preliminary document’s absolute-rating table; verify functional operating limits for your equipment.
The roadmap does not establish an exact RGB/TTL connector, pinout or voltage. Obtain the model-specific electrical specification before choosing a controller or cable. Current production and availability must be confirmed for every model.
Differences to resolve before design approval
N104STN01.0: keep the revisions separate
The March 2024 preliminary specification lists 450 cd/m² typical and a −10 to +60 °C absolute-rating reference. The Q4 roadmap lists 350 cd/m² and −20 to +70 °C. Do not combine the brighter value and wider range into a single rating.
N150XAN01.0: verify low-temperature use
The reviewed preliminary specification gives −20 to +70 °C; the Q4 roadmap shows −30 to +70 °C. A project needing −30 °C operation requires confirmation of the supplied revision.
N156HAN01.0: backlight and color differ
The January 2024 preliminary document lists 262K / RGB 6-bit and 15,000 h estimated minimum backlight life at 25 °C to 50% brightness. The Q4 roadmap shows 6-bit + FRC and 30K. Those are separate references, not a verified upgrade.
N156HAN01.3: clarify color depth
The January 2026 preliminary document has inconsistent color descriptions between its introduction and table. Confirm the applicable definition; do not assume native 8-bit color. Its viewing-angle data also differs from the Q4 roadmap.
Backlight-hour labels are conditional measurements, not a whole-product warranty. Check the original test current, temperature and end-of-life brightness definition for the revision you will receive.
Plan the panel, touch and controller together
- Confirm the full model and drawingCompare outline dimensions, active area, mounting, connector location and cable bend space. Same diagonal size does not ensure the same enclosure fit.
- Match the signal and powerCheck the exact interface, lane or channel configuration, pin assignment, timing, logic rails and power sequence. Review backlight input and dimming independently.
- Specify the viewing environmentState the ambient and panel-surface temperature limits, cover glass, lighting, viewing direction and operating hours. Brightness alone does not establish outdoor readability.
- Validate a sample in the equipmentTest image quality, startup, sleep/wake, dimming, touch operation and thermal behavior with the actual host, controller, cable and enclosure before approval.
For integration enquiries, see touch screens, LCD driver boards and LVDS & backlight cables.
Development entries need a separate decision
N039VAN01.0, N156HAN01.2 and N215HAN03.0 are marked Developing in the reviewed Q4 roadmap. That historical label is not confirmation of today’s release or supply status. They are excluded from the eight-model comparison above.
For N156HAN01.2, a preliminary specification dated 2 March 2026 is available for review, but it does not replace the missing N156HAN01.1 specification. The .2 document includes conflicting backlight-input entries; obtain clarification before specifying a power circuit.
If one of these models is needed, send the exact suffix, project schedule and electrical requirements through a release-status and specification enquiry.
Common selection questions
Are all AUO N-series LCDs LVDS?
No. The reviewed group includes Digital, parallel RGB, LVDS and eDP entries. Select by the exact model and applicable electrical specification, not the first letter of the model name.
Can N104STN01.1 directly replace N104STN01.0?
A direct replacement has not been established by the reviewed material. The models have different suffixes and source data. Compare their complete drawings, pin assignments, electrical limits and backlight systems, then validate a sample.
Which N156HAN01 suffix should I choose?
Start with the required brightness and host eDP capability, then compare the exact mechanical drawing and revision. This guide lists .0 at 250 cd/m² typical, .1 at 320 cd/m² in the roadmap, and .3 at 300 cd/m² typical; those headline values alone do not prove interchangeability.
Does inclusion in this guide mean the panel is in stock?
No. Confirm quantity, product condition, date code, applicable specification and lead time in a model-specific quotation.
Document basis
- AUO Display Plus CNRBU Q4 2026 product roadmap, dated 12 October 2026, PDF pages 19–20: roadmap-only entries and revision comparisons.
- N104STN01.0 preliminary specification rev. 0.1, 19 March 2024: RGB interface, brightness and temperature reference.
- N150XAN01.0 preliminary specification rev. 0.1, 8 May 2024; N156HAN01.0 rev. 0.1, 5 January 2024; N156HAN01.3 rev. 0.1, 27 January 2026: version-specific comparison data.
- N156HAN01.2 preliminary specification rev. 0.1, 2 March 2026: separate development-model review.
Summarized for selection on 25 November 2026. Open each linked product page for the detailed source notes. Request the applicable controlled specification and drawing for the supplied panel; this guide does not identify a preliminary document as the latest released revision.
Build a shortlist we can review.
Send the full model, quantity, equipment application, host interface, temperature requirement and target delivery date. If you are replacing a panel, include clear rear-label and connector photographs.
Request a model & integration review ↗